How to adjust the pressure of the squeegee of the pad printer

Sep 04, 2021

The squeegee is an important part of the pad printer, and the squeegee always affects the printing quality. Today the staff of Agere Machinery came to teach you how to install and adjust the scraper.

First, install the scraper.

①. Loosen the fixing screws of the knife holder clamp plate with a wrench, and take out the soft board and the blade.

②. Clean both sides of the hard blade with a rag and solvent.

③、Cut a new scraper blade of appropriate length according to the plate length.

④. After the hard blade and the new scraper blade are superimposed, they are pushed into the gap between the clamping plates of the knife holder.

⑤ Adjust the distance between the scraper blade, the hard blade, and the blade holder to a proper distance.

⑥. Use a wrench to start with a screw in the middle, and tighten one by one to both ends of the knife holder splint.


Secondly, adjust the scraper.

① Generally, the cutting angle of the scraper and the printing plate is between 45-65 degrees. The scraper angle of the line version should be larger, and the scraper angle of the layered version should be smaller. The specific needs to be adjusted according to the actual production situation.

② The distance between the doctor blade and the embossing rubber roller is generally adjusted to about 5cm, and the specific adjustment needs to be adjusted according to the actual production situation.

③ The pressure gauge of the squeegee should be between 0.1-0.3, and the pressure should be as small as possible when the ink on the layout can be scraped clean.


Third, matters needing attention.

① The new squeegee is installed at the same center position as the printing plate, and the length is 20-30mm longer than the printing plate.

② During the cutting and installation of the new scraper blade, care should be taken to avoid damage caused by the collision of the blade and hand injury.

③. The distance between the new scraper blade and the hard blade and the knife holder clamp plate is operated according to the technological requirements: the distance between the hard blade extending from the knife holder clamp plate is 25mm-30mm, and the distance between the scraper blade extending from the hard blade is 3mm-5mm.

④. After the scraper is installed, the scraper blade should be parallel to the hard blade and the knife holder clamping plate, and the scraper blade should be flat and straight.